I am trying to run power under ground in conduit and would like to know what size wire to run. Now it wont flip back on but it is still raining hard. Wouldnt turn back on for a while even after manually flipping the switch. with UV, Ozone and Hydroxyl Radicals. If you're researching Blue Essence, we're more than happy to help you figure out the best solution for replacing, upgrading, or repairing your system. Hi Carlos, Im not familiar with working on those timers, a built-in to the back cover for Power-Flo pumps. Some motors, esp. Hi Kenny, not to my knowledge, you should see some display even without gas hookup. Reset is immediate after error is corrected. News Reporter Reveals On Live TV That Shes Been Secretly Recording . I would like to repair it if possible. hayward blue essence troubleshooting Went on to fill with water again & put on normal cycle and still was not getting a full prime. This year, I noticed at times that the flow rate on low speed is less than it was last year. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. Fault with the pump wiring. See if your test button has popped out on the outlet, or perhaps you have one on the breaker, a test/reset button. It looks like no one has them in Stock and if I cant filter the pool, then it wont be usable. hayward blue essence troubleshooting. There can be multiple reasons for a pool pump not priming correctly. I have a Hayward super pump 1.5 hp. larger hp motors, are not reversible. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. Blocked air vents and no air flow is also a possibility. If a LED is ON, check to see if the flow switch was installed correctly. The shaft is accessed in the rear of the motor, behind the centrifugal switch. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. So it seems its changing speeds from slow to normal or is shutting off and immediately turning back on. what could be the issue? Hayward Tristar VS manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true has some good troubleshooting tips. Rob, the air leak is coming from the pump, or before the pump. Essentially, its probably something loose/broken, or a bad capacitor, which is like the battery to help it get up to high speed. "keywords": "",
It just started leaking at the top plumbing connection. Remove the filter cartridge to see if it continues. Increased flow this year may be from the new sand, and higher flow makes it easier for air leaks to appear. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. All pipes are 1.5 and solidly installed with primer and high quality glue for the PVC used. The price seems steep ($500+ for the pump) and it seems only Leslies carries them. IF so, replace the fitting, or pack pool putty or silicone around the fitting, and leave it running for 24 hours, until the sealant sets up hard. 7. When running through all these checks and balances if it is noticed that there is not bond wire or that the tightening screws are not all secure, correct the issue. We cannot get it going again. Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. the motor makes humming sound but nothing happened, then the motor became burning hot. Is the water level ok in the pool, and the skimmer weir is not stuck? I will try that tonight. Features: Replacement for Hayward T-CELL-5, GLX-CELL-5-W and Aqua Trol Suitable for pools up to 20,000 gallons Comes with a 15 foot cord Clear housing for visual inspection of cell No need for re-plumbing, direct fitting threads Meets all original factory specifications Reverses polarity to automatically clean cell i removed the filter fingers and cleaned numerous times. Loose connections or insect infestation on contacts, or loose breaker etc, could also cause a different type of start/stop problem, very rapid. If all good, check the capacitor, at 9 oclock, looking for bulging or cracking or burned marks. To Become a Customer please Click Here > Skip to the end of the images gallery Skip to the beginning of the images gallery HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 Sku: BLUE ESSENCE-35 Be the first to review this product Hi Mark, in looking at the owners manual https://www.intheswim.com/images/PDFs/E1964-Manual.pdf perhaps there is a minimum speed setting that is set to high, or the programming Day/Time/Speed is set up to permit high speed only? The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. Good luck! Hi William, yes an air leak, is what I call it. Capacitor is a battery in the back of the motor, at 9 oclock that assists in starting the motor, if the capacitor was weak, that may draw more amps from the breaker. If from the center of the lid around the stem, you can replace the two small stem o-rings, but sometimes the stem is worn down and needs replacement. Is the replaced pump and motor problem? Hayward Pool Heater Troubleshooting - In The Swim Pool Blog Thanks! Hi when you say it shuts down, I assume you mean that the water stops flowing? Ive done the reset and it still showing 4300. A warranty process with Hayward may take awhile, a few weeks this time of year I would think. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the Dec 14, 2021. Usually get 3-4x that long. If symptoms continues with the filter on recirculate, you would have different problems, like restriction or obstruction in the pipes. Salt Chlorinator Problems - Repair or Replace? - InTheSwim Pool Blog If so, the issue would reoccur again, after vacuuming usually. *new pool owner of a big above ground pool* hello I bought a home it came with a pool the pump says Hayward. Oftentimes I reassemble the pump only to find the diffuser laying on the ground (doh!). I tried replacing that oring and the leak got worse somehow and it just doesnt feel like there is any pressure when tightening the 6 bolts that hold the pump and motor together. It is not just the connection that is leaking, the pump body itself has sprung at least one leak near the neck of the top fitting. If the gears are moving, then power should be coming out of the timeclock to the motor. Blower will operate until error condition is corrected. Use a flashlight, and you should see gears moving thru the small view hole. Pumps need to be fairly air tight, and water tight to avoid drain down when they shut off. Salt cells create cloudy bubbles, Ozonators too. Once we turn the pump on it runs good for a couple of mins then then once it builds up pressure the water pressure into the pool slowly stops. Hayward pumps use different shaft seals, you can find the correct one here: https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG . I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. Do you think its the capacitor and I can get another one from Hayward, or possibly mis-wiring? Air could also be entering the pump from the threaded pipe or union that is attached to the inlet port, which may also spray or drip when the pump shuts off. Check the serial number on the pumps sticker. Recently I started getting a loud vibration hum from my hayward pump. Any suggestions? If still nothing, look for damage in the rear of the motor, something burned, melted, loose, or pinched or cut wires. I have 2 pumps, Ecostar for pool and Tristar VS for my waterfall, the pool pump is working fine, the Tristar will not come on, when I use my Omnilogic app or or the panel to turn on it just says-paused/valve change, but there is no valve change going on-having a Memorial Day party this Saturday and getting a bit freaked out, I have tried calling support, but they put me on indefinite hold, and I cant seem to get in touch with pool company-please help. If none of those things, perhaps the filter grid needs to be soaked in a Filter Cleaner, to remove oils or minerals that have clogged the pores of the fabric. March 2023 Issue - Donovan's Bookshelf If the motor hums, buzzes, or tries to start, but trips the breaker (or not), could be a bound-up shaft, super clogged impeller, bad capacitor, or bad motor. Hi Davy~ Hi Stephen, your spa waterfall, is that a spillover or an actual waterfall feature? Power can be checked at the motor terminals, with a multimeter set to AC volts. Hi David, spilling water on the motor is no problem, they do fine outside in the rain (flooding is a different story) Have you checked the GFCI test button on the outlet? Thanks, Hi Nancy, this is a common problem water leaking out of the backwash line, while filtering. Be sure the wiring is tight on both ends. Gauge was reading between 6 and 8 on filter container at this time. partially collapsed, or partially clogged skimmer line. If its not the cord, I would suggest the filter, cleaning the fingers with a good soak to de-scale and de-grease. hI, the impeller ring should go small side toward the impeller, they are often marked as such. Have a Hayward SuperPump. "primaryImageOfPage": {
Does anyone know what Im talking about and/or know how to repair? A large pair of channel type pliers can be placed on the impeller, over a cloth, and given some persuasion. We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. If the shaft is free turning but it makes a hum or buzz sound, usually followed by a tripping breaker, check the capacitor, it may have failed. Troubleshooting Guides | Support Center | Hayward Residential and It had a non Hayward motor installed before. Could be a loose lid, or the basket not re-placed properly, and a clogged pump impeller. My pump is one horse power. Hi Jim, as I like to say, the problem lies, where the power dies. Ohms reading should be between 0.5 and 1.0 ohms max. Approx. I doubt you damaged anything, or have any big issues, should be OK. Check the wiring of the pump cord, comparing to the wiring diagram printed on the motor, to be sure that they are connected properly, should be wired for 115V (not 230V). 3. inspect clock and rear of motor for any obvious signs of damage, like watermarks, dirt, insects or something burned or melted I heard like a crank sound, as if somethings stuck between a propeller if there is. Missing air bleeder sock or strainer cap If the filter was a problem, you may notice higher than normal filter pressure (compared to the old pump). Hi Michelle, If the pump and motor are too large and powerful for your filter size, it would create this situation. Leaks can also come from loose drain plugs, or loose bolts on the seal plate, connecting the motor to the pump. Hi William, the on/off switch is sold as an entire end-cap piece, including the rear cover, the yellow wire would not be a part that is sold, I suppose you could make it yourself ? So My pool pump is two speed and I have it set to run for 3 hours in low speed and 5 in high. Hi Rachel, Im guessing a Hayward Perflex DE filter? Water temperature is above 140 degrees F. Make sure that either 120VAC or 240VAC input power is connected to the proper screw terminals at the Aqua Rite control. men's rhinestone dress shoes. Hi, might have been a small clog in the pipe. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. Hi I have a Hayward aquatrol above ground pool chlorine generator system. Christin, many aboveground pumps plug into a GFCI outlet, check that the TEST button is not popped out. Hi Larry, When DE is coming back into the pool, its usually: Do you have any advice? I turned it on and it ran fine for about one hour. Baal School; Skill Training for Girls When I try to turn on high speed it sounds like its jamming and then the breaker trips. If it is a 15amp breaker, but the pump wants 9amps and the aquatrol wants 7 amps, (for example, made-up numbers) thats a total of 16amps, too much. *. This time around I purchased the t-3 cell model since my pool is below 15k gallons. $579 + Free Shipping in USA. My check salt generator station even after I clean it out. Can you manually get it to rev-up on a higher speed? We have all these parts here: https://www.intheswim.com/c/valve-parts, I Installed a new Hayward VCSB216V solar pump. I came back after going out and my older Hayward pump was off. The pump should really be on its own breaker if possible. If your shaft IS spinning freely, other causes of a tripped breaker include loose wiring, broken wires, water in the wire conduit, wires inside the motor touching other wires or the metal motor casing, insect infestation in the time clock. As you found, if the motor sounds just as loud when it is pulled out or removed from the pump housing its usually the bearings, which normally last for up to 10 years, not in this case it seems. It could also be a loose switch in the back of the motor. It is brand new. hayward super pump C48L2N134B1. Hi, make sure that the switches are not loose, the centrifugal switch on the end of the shaft and the Stationary switch at 6 oclock. Hello there, if he customer wants to install a VS pump (required in 2021 for all new pumps), they could do that now. I would call back the electrician, he may have fumbled this while wiring it, such a problem is rare, and could hardly be blamed on the manufacturer, but if your electrician says that its not his fault, have him put in writing on company letterhead, what the defect of the motor is which can help you in getting warranty assistance. I have a hayward sp2610x15 1.5hp pump that I got in May 2017. They disparate as they move through the pool. Step 2: Did you properly install your switch? On your filter (X-Stream and Voyager) there are two large wing nuts under the lid which secure the pressure gauge and air bleeder. Thats good such frozen motors are common in the spring. I reached into the impeller and grabbed it but it seemed still tight. I have a max-flo vs pump and it cant seem to stay at a high rpm for any long stretch of time when its sunny. The fuse is meant to protect the heater from 115V, as the voltage past the fuse should be like 28V, stepped down after the transformer. Hopefully the GFI then holds. So yes it could be the filter, very clogged and in need of a deep cleaning, but probably not a filter mechanical issue. So we have power to the pump. It is being practiced by thousands of pool owners just like you. }
. Do we need a new pump or can the electrical cord be replaced? Ive tried setting up the vacuum with power on and power off and its no different. It shouldnt be overheating, not in twenty seconds, but I suppose it could. Hi Davy, my pump is on a timer and will occasionally fail to turn on in the morning. Is that a result of all the water that got in the equipment during the storm? I have a hayward pump installed as a new this March, 1.5 hp motor with a 23 inch filter to support a 12,000 gallons pool, it was working properly the first 3 months occasionally motor shut off and it wasnt by the breaker, since a week motor keep running only by 20 ,ins and suit off, touching the motor it is hot, I review filter pressure it is 15 psi, it is the same since installation. I turned the gas off to it. Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. Look closely at the centrifugal switch in the middle/center/end of shaft, make sure its tight and intact. When I touch any other speed button, nothing happens. Missing push-pull valve o-rings, DE powder getting inside of the grids however thats something notable and the fact that it only does it on Low Speed, also unique. It leaks where the seal plate connects to the pump/strainer housing. All On Jandy valves, the spurt may be from the lid, or from the center of the lid around the stem, from a broken or missing grease cap (grey valves), or from a crack/damage. Hi check that the pump is not drawing air in, most common areas are around the pump lid, drain plugs and most common, the threaded pipe coming into the pump, which should be sealed with thread sealant like Teflon Tape and/or RTV silicone. If the blower prover switch opens unexpectedly during operation the control will shut down and attempt to re-light. If your pool is fairly small, without spa and water features, you can also consider using a Pentair SuperFlo VS pump, which has fewer features than the Intelliflo, but also costs much less. I have 2 extension cords running to plug it in. "
vacuum on waste last night. Thanks. Thanks. However, we are not able to remove the pump. I have a pre-2008 Northstar pump and it seems to be losing air seal. Hayward Blue Essence Troubleshooting, Gas pressure is ok. Any ideas? Can I turn on this pump without water to check whether the motor is running? Thanks in advance for any help. On the return side, after the heater, the return valve should also move, with Spa Jets fully open and pool returns fully closed. There is not much that can be done to increase flow rates for a smaller pump, with exception to reducing plumbing restrictions with larger pipe size and less elbows, etc. Is there a reset button or do I just need to wait until the water evaporates and it should turn back on? Could be dangerous! Cheers! I have a brand new Hayward super pump, replaced the one that just died. Third, is there a valve closed after the filter, or some other obstruction? To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. Disconnected the chlorination device, and direct connected it eliminating that. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. A whirlpool in the skimmer that is deep enough can suck air into the pipe. Thanks. that would be rare, very rare. Any ideas or what else to check? from Troubleshooting pool heaters is a methodical process, or a process of elimination. HI Sang, check the capacitor, or just replace it, they are cheap, it is the large black cylinder at 9 oclock in the rear of the motor. Does it mean the problem is on the pump itself ? Any ideas as to how to fix this? Hi, my Hayward pump is about 5 years old. Check the wiring. If they are within range, replace drive. Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. Is it time for a replacement pump? Hi Rod, if the pump motor was submerged, then it is D.O.A. HI Bernard, sounds like it could have cavitation, or a pipe diameter that is too small but pipe is the same. Hi Deb, probably a bad outlet or a bad cord, or a loose connection on one or both of those. It only blows air but when I take the lid off water comes out and the basket over flows. Is the motor set to accept 220V, and matching what you measure at the motor terminals? For more info, see page 36 of the Hayward heater owners manual. We had a pool built in FL in Aug 2018 with variable speed Hayward TriStar pump. Look for 4 other bolts, or a clamp band, to pull the motor/impeller out of the wet end, or the pump housing. Should there be some form of gasket here? If the pump runs air tight, but slowly drains out over an hour or so, that is usually a pressure side (after the impeller) air leak. Not sure what would cause that?!? Capacitor or needs new motor?? After communication is established, if it is lost for 30 s, the error will be displayed. Check that the motor wiring matches input voltage, if the motor can be wired 110/220V. there is an air leak, on the pump lid, or around the pipe that comes into the pump, or the pump drain plug. No lights are coming on as if no power. Thanks, Steve DeGray. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. I do not think its the breakerits relatively new. Work through the chart below if your heater displays the following error codes. They just reopened my pool. I am getting a CEL code and the heater will not run. If so, you need stronger hose (or pipe), or add another suction pipe (and wall fitting). I just purchased a new pump for my pool. Finally, in cases of very hard water, some of your sand bed may have calcified, and need to be replaced. Hi Rudy, clicking on/off sounds like the switch in the rear of the motor, you may find either the centrifugal switch (dead center) or the stationary switch (6 oclock), may not be fully disengaging, or may be loose or bent. Has been running great. Its a little over 3 years old and the cell checked out fine. How did it end up? It overheated very badly, even burning the hayward sticker off the pump itself maybe a month ago. Inspect the motor for any burns evident on the casing as many times, an overheating motor will be shorted across the windings, and will soon fail. Davy, BBC News - Dear This Week: your views on our show runs normal on 110 but does not make any sound when set on 230 and wired accordingly. What am I not doing? Could this be my problem? Plunger was a good idea, a Drain King can also be used, from the pump, to blow debris back to the skimmer. I can turn the switch to low and it will start and run then switch to high. Before I purchase all new control board assembly, does this sound about right? Typically, any dilemmas with your Hayward pool pump are likely related to either electrical or plumbing situations. Check it out, it could start a fire! Pushing down on the handle briefly (pump off) can often dislodge the debris, and no gasket replacement is necessary if you are lucky. Remove all of the bolts around the top and pull out the Filter Nest, or all of the fingers. Big difference, but other than that, they operate pretty much the same! 1. Flipped the timer on, water shot up about 10 feet and went all over me and the timer and the breaker blew. There is also a leak somewhere in the system because there is water on the pad. No loose wires or insect infestation. Motors are hot normally, 140 degrees or so, but if it shuts off and then resets and turns on again after 15-20 mins, it could be overheating, from voltage problems, loose connections, motor board, switch or capacitor wiring problems, or internal winding shorts. Hi Freddy, usually a clicking noise may be a relay, which are used in control systems for pools. HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 - MT Pool Distributor Is it possible that the filter is the problem? Automatic restart is 2 minutes after the error is corrected. Thats all I can think of now. If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. You can check the visual motor check (if you have an intermatic clock), to see if the motor gears are turning, which means the timeclock motor is good and the power from the breaker is good. We have a Hayward 1.5 lx. Is there a thicker housing oring that could be installed to fix the leak? I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. We just opened our pool up cleaned everything out put new D.E. My pump motor runs for 3-5 minutes ant then shuts off for about the same time. Im being advised by an electrician that my Hayward pump has a dead short in it. This is a black cylinder located in the back of the motor, at 9 oclock, which acts as a battery to give the motor extra juice to start. 1.5 hayward pool pump motor clicks on and off rapidy. gives you instant access to PDF files. Problem is now the pool will not clean up (algae) and the pump is slow to prime. 2 No loss of water level in the pool Any thoughts? Big mistake! "@type": "BlogPosting",
Specialties: Cycling, Kickboxing, The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. There must be a leak. Get support by contacting us online, hayward Below is the troubleshooting guide for Hayward pool heater error codes. If thats not the issue, is the pump sized correctly for the filter, and not under/over sized? Hi Joe, the Perflex DE filter has a few dozen flex tubes covered in a mesh fabric. Hi David, that would be my first guess, assuming that the power leads are tight, and connections or switches arent loose in the back. The pump has its own breaker as well. Motor wiring is pretty simple, green to ground and the other two wires, doesnt matter which one, go to terminals L1 and L2. Now, if your motor has cooled off, but wont start again, or make any noise at all, as you say i would check the power (volts) going into the motor, put the multimeter probes (set on 240V+) onto the two brass terminals of the motor terminal board, where the two incoming wires connect. If no power there, check the timer, if no power there, check the breaker, if no power there Is the main breaker in the house on? Hi Paul, Ants can be a problem, when they get around motors or circuit boards, but it sounds like a pump motor problem, and could simply be a weak capacitor, in the rear of the motor (black cylinder). I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business.